Contact Us Sitemap

Process Gas and Liquid Dryers
Typical Custom Applications

HIGH-PURITY AIR HYDRYER® 

  • Electronics plant
  • 4,592 scfm at 135 psia
  • Outlet specification:
    0.1 ppmv H2O
    0.1 ppmv CO2
    5.0 ppbv CO
  • Catalytic purifier
  • Two-stage cooling
  • Local PLC control
  • Dual-tower adsorbent beds
  • Electric heater with SCR

PROPANE HYDRYER®

  • Underground storage site
  • 4,800 gpm at 240 psig, saturated with water
  • <20 ppmw water outlet
  • Activated alumina
  • Air-cooled condenser
  • Parallel on-stream vessels
  • Multiple electric heaters
  • Local high- and low-voltage electrical enclosures

BUTANE HYDRYER®

  • Refinery
  • 4,600 BPSD
  • <10 ppmw water outlet
  • Steam heater
  • Dual API pumps
  • Remote, redundant PLC
  • Factory insulated
  • Galvanized base and piping supports

CO2 HYDRYER®

  • Beverage industry
  • 44,501 lb/hr
  • 292 psig
  • -80°F dew point
  • Sulfur removal
  • Factory insulated
  • Metal seated valves
  • Selective adsorbent

N2 HYDRYER®

  • PET processing
  • 2.0 psig
  • 500 SCFM
  • -40°F dew point
  • Organic removal
  • Blower purge
  • PLC control
  • Molecular sieve adsorbent

VENT-GAS HYDRYER®

  • Chemical plant
  • 1,200 lb/hr
  • 36 psig
  • 300 ppmv H2O in
  • 0.1 ppmv H2O out
  • Closed-loop regeneration
  • Explosion-proof electrical enclosure
  • Manual switching

LANDFILL GAS

  • Waste to energy plant
  • 1,070 SCFM Biogas
  • 70% CH4, 20% CO2, 1% H2S, balance water and trace elements
  • 30-35 psig, 105°F inlet
  • Outlet dew point of 38°F
  • Stainless steel materials in contact with process
  • Class 1, Division 2, Group C & D electricals
  • NEMA 4X “Z” purged electrical enclosure

BENZENE HYDRYER®

  • LAB plant
  • 525 lb/hr with 1,600 ppmw water
  • <16 ppmw water outlet
  • Split stream regeneration, no loss of product
  • CSA electricals, inspected at factory
  • Fully assembled, ready for piping and electrical connection
  • CRN vessels+

ARGON HYDRYER®

  • Air separation plant
  • 41,700 SCFH crude argon
  • 62 psia
  • 4% oxygen inlet
  • 2 ppmv oxygen outlet
  • -100°F outlet dew point
  • Catalytic deoxo bed
  • Recirculation blower to dilute oxygen
  • Finned pipe coolers

PROPYLENE HYDRYER®

  • Gulf coast refinery
  • 14,300 BPD at 400 psig
  • 0.5 ppmw outlet water
  • Dual steam heaters
  • Split stream regeneration – no loss of product
  • Valve status lights on local PLC enclosure
  • Galvanized base with deck plate

HYDROGEN HYDRYER®

  • Chlor-Alkalai facility
  • 28 MMSCFD @ 410 psig
  • Eight vessel system
  • HCl removal, lead-lag
  • Sulfur removal
  • Deoxo/RCI catalytic conversion
  • Heat recovery
  • Final moisture removal

AIR PRE-PURIFIER HYDRYER®

  • Air-separation plant
  • Combination chiller/dryer
  • 1,441 SCFM, 125 psia
  • 400 ppm CO2
  • O2 cleaned
  • O2 rich regeneration
  • Remote PLC panel
  • Outlet specification:
    <0.1 ppmv H2O
    <1.0 ppmv CO2